Follow us:            

Cartridge Dust Collector

Cartridge Dust Collector
Platinum Series
cartridgethumb

Discover The Power Of The New Generation Of Vertical Cartridge Dust Collectors

Airex Industries PlatinumTM Series Dust Collectors are different from other dust collectors. Their ability to filter highly-contaminated air volumes in an extremely compact format is what sets them apart from the rest. As part of an efficient compressed air self-cleaning system, the cartridges allow for the continuous filtration of sub-micron dust particles with a constant differential pressure loss.

Our PlatinumTM dust collectors have doors and a manual cam system that require no tools and allows for an easy cartridge change out.

Main Advantages At A Glance

High Filtration Capacity
Models from 2 to 224 cartridges and up to 100 000 CFM capacity.

Custom Engineering
Special needs and custom designs available with PlatinumTM systems.

Low Inital Cost
The optimization of our design and assembly technics allows us to offer highly competitive prices.

Vertical Cartridge Design
Unlike horizontal cartridge designs that reduce filtering surface efficiency by up to 30%, Airex Industries PlatinumTM series dust collectors maintain a 100% filtration rate at all times.

Vertical Filtration Principle
How The Cartridge Dust Collector Works

The dust-laden gases enter through the side intake of the dust collector’s hopper, under vacuum or pressure (except for bin vents, where the air comes in from the bottom).

The gases are then filtered through the cartridges and exit through the openings into the clean air plenum. The clean air can either be channeled outside or re-circulated depending on the application.

Advantages

Fast, Simple and Safe Cartridge Replacement

Cartridge replacement is performed outside the dust collector and requires no tools. This eliminates the need to work within a confined space and allows the worker to access the cartridge without getting dirty. The cartridge comes with a rectangular top plate that simplifies manipulation and eliminates potential installation errors.

Continuous Operation

Unlike other types of dust collectors such as the shaker, the cartridge dust collector does not have to be stopped in order to remove and clean dust particles from its filters.

Economical

The cartridge dust collector is an economical choice because it requires minimal maintenance: only periodic cartridge replacement is necessary (depending on the application).

Filtration Technology

We Have the Right Filtering Media for Your Needs

In terms of performance, one of the most important criteria during the initial design of a dust collection system is the proper selection of the filtering media.

There are several cartridge models providing adaptation flexibility based on the characteristics of the various types of aerosols. The filtration effectiveness of Airex cartridges can achieve a level equivalent to HEPA, classified as MERV 16. In fact, a single cartridge has a total filtering surface that can reach up to 315 sq. ft. The compact aspect of such a filtering medium makes it a highly prized solution when the available space is limited.

Common Features

End Cap and Gaskets
Our standard end caps are made of galvanized metal (16" x 14.25") while our D-Shape gaskets are fabricated with continuous rubber (0.5" W x 0.625" H).

Operation Temperature
Cartridges maximum continuous operating temperature is 250 °F (120 °C) while the maximum short term operating temperature can reach up to 295 °F (145 °C).

Weight and Dimensions
Weight : 22 lb
Height : 36"
Outside diameter : 12.75"
Inside diameter : 8.3"

 

  85% Cellulose/
15% Polyester
8 oz Spun Bond
Polyester
Cell / Poly
with Nanofiber
8 oz Spun Bond
PTFE
Filtration Area 315 ft2 130 ft2 315 ft2 130 ft2
Efficiency 99.7% @ 0.5 microns 97% @ 0.5 microns 99% @ 0.37 microns 99.4% @ 0.08 microns
MERV 9 @ 840 cfm 10 @ 500 cfm 15 @ 840 cfm 16 @ 500 cfm
Permeability 17 cfm / ft2 @ 0.5" H2O 20 cfm / ft2 @ 0.5" H2O 25 cfm / ft2 @ 0.5" H2O 5-8 cfm / ft2 @ 0.5" H2O
Pleat Count 315 130 315 130
Pleat Depth 2" 2" 2" 2"
Resistance
Acid ** *** ** ***
Alkaline * * * *
Abrasion *** **** *** ****
Accessories
Enhance Your Performance and Security

Some options like the SpeedFXTM can vary motor speed and energy consumption thus improving efficiency.

A number of Airex accessories aim to meet NFPA regulations, preventing against fire and explosions while better protecting workers and facilities.

Fire Protection Accessories

Abort Damper
Connected with a proper spark or fire detection system, the abort damper redirects exhaust air into the atmosphere as soon as a spark is detected.

Blow Back Damper
Ensure there is a seal, if a fire or explosion occurs in the dust collector, preventing return of smoke and fire to the shop by the intake ductwork.

Explosion Vents
The explosion vents redirect a propagating flame or explosion to atmosphere via pressure rated washers.

Rotary Air Lock
Designed to control the flow of discharge material from a dust collector or other type of process while maintaining an air seal.

Spark Detection & Fire Extinguishing System
Counters the spread of fire with a temperature probe and sprinkler. : Spraying the collector and stops the blower (eliminating oxygen intake).

Preventive Maintenance

Use a Proactive Approach to Increase the Lifespan of Your Unit

Like other industrial equipment, a dust collector has an assortment of components that you need to keep an eye on to ensure the unit is operating optimally. If these components are not maintained, the company could find itself in a potentially risky situation in terms of health and safety.

Airex offers a preventive maintenance contract that can increase the useful life of your dust collection system and its accessories. This type of program is also an excellent strategy for avoiding the unforeseeable in terms of breakages and unit stoppages.

By investing in the maintenance of your dust collector, you will also save money by avoiding emergency repair costs that are of course much most onerous over the medium and long term.

Stay Alert for Early Signs of Deterioration

Visual Inspection
Be vigilant to the appearance of corrosion, dust accumulation or even wear and tear of your system.

Variation of Noise and Vibration
Listen for a compressed air leak, fan vibration, or even an unusual sound from your system.

Tracking Operation Parameters
Make sure the performance indicators stay within the prescribed limits of your system.

Specifications - PS

Model /
Nbs of
cartridges

Valves
Qty
Dimensions Filtration Area 
Weight
(lbs/kg)
A
B
C
Cellulose /
Nanofiber

Spun Bond

in mm in mm in mm ft2 m2 ft2 m2 lb kg
PS-04 2 133” 3379 91” 2311 47” 1193 1260 117 520 48 1800 810
PS-06 2 133” 3379 106” 2692 45” 1143 1890 176 780 73 1999 900
PS-09 3 147” 3733 118” 2997 65” 2794 2835 264 1170 109 2274 1023
PS-12 4 177” 4419 105” 2667 87” 2895 3780 352 1560 145 3301 1485
PS-16 4 175” 4368 119” 3022 87” 2895 5040 469 2080 193 3706 1668
PS-20 4 187” 4724 133” 3378 87” 2895 6300 586 2600 242 3988 1795
PS-24 6 195” 4953 120” 3048 115” 2921 7560 703 3120 290 5137 2312
PS-30 6 187” 4749 134” 3404 128” 3251 9450 879; 3900 363 5618 2528
PS-36 6 213” 5410 148” 3759 128” 3251 11340 1055 4680 435 5991 2696
PS-42 6 255” 6477 162” 4114 128” 3251 13230 1230 5460 508 7084 3188
Specifications - DCCH

Model /
Nbs of
cartridges

Valves
Qty
Dimensions Filtration Area 
Weight
(lbs/kg)
A
B
C
Cellulose /
Nanofiber

Spun Bond

in mm in mm in mm ft2 m2 ft2 m2 lb kg
48 8 89” 2261 162” 4115 257” 6528 15120 1392 6240 583 6930 3150
48D 8 89” 2261 162” 4115 194” 1928 15120 1392 6240 583 6300 2864
50D 10 75” 1905 202” 5131 204” 5182 15750 1450 6500 607 6732 3060
56D 8 103” 2616 162” 4115 207” 5258 17640 1624 7280 1680 7233 3288
60D 10 89” 2261 202” 5131 205” 5207 18900 1740; 7800 729 7307 3321
64D 8 118” 2616 162” 4115 219” 5563 20160 1856 8320 778 8100 3682
70D 10 103” 2616 202” 5131 215” 5461 22050 2030 9100 850 8212 3733
80D 10 118” 2997 202” 5131 217” 5512 25200 2320 10400 972 9193 4179
84D 12 103” 2616 243” 6172 222” 5639 26460 2436 10920 1021 9339 4245
96D 12 118” 2997 243” 6172 222” 5639 30240 2784 12480 1166 10442 4746
112T 14 118” 2997 283” 7188 222” 5639 35280 3248 14560 1361 12513 5688
128T 16 118” 2997 324” 8230 222” 5639 40320 3712 16640 1555 14587 6630
144T 18 118” 2997 364” 9245 222” 5639 45360 4176 18720 1750 16425 7466
160T 20 118” 2997 405” 10287 234” 5944 50400 4640 20800 1944 17584 7993
176T 22 118” 2997 446” 11328 245” 6223 55440 5104 22880 2138 18725 8511
192T 24 118” 2997 486” 12344 257” 6528 60480 5568 24960 2333 19864 9029
208T 26 118” 2997 526” 13360 269” 6831 65520 6032 27040 2527 21785 9902
224T 28 118” 2997 567” 14402 281” 7138 70560 6496 29120 2722 23680 10764

HEPA Air-Purification Cabinet

HEPA Air-Purification Cabinet
cabinethepathumb

A versatile filtration device that can adapt to all circumstances

The HEPA air-purification cabinet is designed to extract smoke, dust, odours, microbes and any other type of airborne contaminant. This portable, versatile device is easy to integrate into your work environment without requiring the involvement of a professional.

With its high-efficiency multi-stage filtration design, the HEPA air-purification cabinet is an excellent solution for supplementing the existing ventilation system. The unit reduces the risk of contamination within the space where it is installed, thereby protecting the health and safety of the people in their workplace.

 This device is ideal for professionals who tend patients in a context where physical distancing is impossible.

Main advantages

Filtration efficiency
The cabinet delivers a maximum output of 595 m3 per hour (350 CFM) of purified air and has an efficiency of 99.7% at 0.3 µm using a HEPA filter. The unit can be modified with an ULPA filter to achieve 99.9995% efficiency at 0.12 µm.

Versatile use
Different usage configurations are possible, such as at-source extraction, ambient-air filtration in recirculation mode, or creation of a negative- or positive-pressure isolation chamber.

Advanced multi-stage filtration
The multi-level filtration design preserves the service life of the HEPA micro-folded filter

Filtration principle
Advanced multi-stage filtration

The HEPA air-purification cabinet is equipped with filtration technology for decontaminating the ambient air through three separate filtration stages that, when combined, puts out purified air of equivalent quality to an industrial filtration system.

When contaminated air enters the cabinet, large particles are first extracted by the pre-filter. The air is then directed to the HEPA filter, which intercepts the remaining fine particles. Finally, just before reaching the unit’s outlet, the activated carbon filter absorbs odours, smoke and other types of chemical pollutants in the air stream.

Usage contexts
at source extraction

At-source extraction

 Adding an extraction arm provides the ability to filter out contaminants at the source before they enter the environment. This configuration type is especially valued by dentists, whose work generates aerosols from body fluids.

ambient air extraction

Ambient-air extraction

Public areas such as waiting rooms and stores are places conducive to the spread of microbes and viruses with high epidemic potential. This is where the unit’s ambient-air filtration in recirculation mode really comes into its own.

isolation chamber

Isolation chamber

The HEPA air-purification unit is entirely appropriate when it’s necessary to confine a patient in a hospital setting, when that patient is infected with a contagious disease. The unit can remove the air from the patient’s room to the outside in order to create negative pressure. Likewise, when a patient is immuno-deficient, the reverse process can be applied by converting the room to positive pressure through the air supply generated with the device.

Electronic Air Purifier

Electronic Air Purifier
Ionex Series
electronicairpurifierthumb

Nanoscopic Air Filtration Technology, An Unrivalled Solution

The Ionex Series electronic air purification unit is without question the ultimate decontamination solution. This technology is intended for environments requiring stringent control of the ambient air quality.

This patented Ionex Series electronic air purification system eliminates ultra-fine particles, as well as viruses, bacteria and mold. In addition, this air purifier is capable of filtering volatile organic compounds (VOCs) as well as smoke and odours.

Main Advantages At A Glance

Outstanding efficiency rate
The unit provides a maximum flow rate of 500 m3 per hour (294 CFM) of clean air with its filtration technology capable of achieving an efficiency of 99.7% at 0.003 microns.

No mercy for airborne contaminants
The unit doesn’t just filter aerosols, bacteria and viruses; it eliminates them using powerful, 24,000-volt electric shocks.

Continuous operation
The automated cleaning feature reduces maintenance and maintains optimal filtration efficiency at all times.

Filtration principle
Unprecedented performance

For comparison, high-efficiency HEPA filter technology has an efficiency of 99.97% for 0.3 µm particles. The ULPA filter has a higher filtration capacity of up to 99.9995% for 0.12 µm particles. Although the performance of these types of filters is very respectable, sometimes these filtration levels are insufficient for some settings.

For example, consider some sensitive environments where the air quality has to be 100% pure: laboratory cleanrooms, hospital settings (operating room, nursery), long-term care centres, high-tech factories, to name just a few.

The Ionex Series is designed to decontaminate air at the nano-scale. Its leading-edge electronic air purification method positions it as one of the most modern, high-performing units in any category. In fact, the Ionex Series can purify 99.7% of 0.003 µm contaminants.

Electronic air purification process
  1. Contaminated air is drawn into the unit.
  1. Aerosols are negatively ionized using a corona discharge inside the enclosure. They are then attracted to a positively ionized collection surface. Therefore, microbes, bacteria and viruses are eliminated by a powerful 24,000-volt electric shock.
  1. The air then moves to a section equipped with activated carbon that effectively removes volatile organic compounds (VOCs), smoke and odours from the airflow.
  1. The air exiting the unit is completely purified and free of particles, microbes and toxic gas fumes.
  2. The unit has an automated self-cleaning feature that reduces maintenance, while also keeping the filtration efficiency at an optimal level.
Specifications
Technical Information
Flow 3 speeds: 200, 350 and 500 m3/h
efficiency 99,7% @ >0,003 µm
Gas removal 800 g activated carbon, 60 mm
Dimensions (W x H x D) 600 x 1680 x 600 mm
Weight 91 kg
Chassis Painted steel
Installation Mobile
Power comsumption 50 -150 W
Sound level 25 - 42 dBa
Operating voltage 198 - 264 V, 50/60Hz
Usage temperature +5...+60 ⁰C