Our ovens meet the requirements of NFPA86. They are class B ovens, i.e.
they are operating at atmospheric pressure. The ovens must not contain
any volatile, flammable, or combustible material otherwise additional
features must be added in order to meet the requirements for class A
ovens.The following list states the standard specifications of our
models FG500-xxxx. Other additional features are also available as
options.
Options
Electrical features
Alarm relay
Alarm strobe light
Alarm buzzer
Open door detector
Circular chart recorder
Digital daily time switch, 7 days/24hours
Hour meter for blower
Incoming disconnect with fuses
Control panel Nema 12
Temperature controller 1/8 din or ¼ din
Programmable temperature controller
Mechanical features
Additional features necessary for Class A ovens
Explosion hatch and venting
Exhaust stack
Thermocouple guard
Motor guard
Shaft/bearing guard
Sliding doors
Automatic door opening device
Electrical specifications
Operating on 600V, 3-phases, 600Hz
Completely wired and tested
Control panel
Terminals for incoming power (disconnect not included)
Temperature controller 1/16 din with type J thermocouple
Heating and ventilation switches
Pilot light
Control panel Nema 1 meeting the CSA requirements
Purge timer
Mechanical specifications
Air recirculation
| Blower |
CFM as specified, 2 w.g. @ 70F
|
| |
Selected AIREX SXB model , class 2S
|
| |
Backward inclined
|
| |
Shaft cooler
|
| |
|
| Motor |
High efficiency TEFC
|
| |
Between 1.5 et 10 HP
|
| |
1800 or 3600 RPM depending on model
|
| |
OSHA guards
|
| |
V-belts type B
|
Burner
Eclipse 040AH / 080AH / 120AH models
Capacities of 500,000 / 1,000,000 / 1,500,000 BTUh
Insulation
Mineral wool ROXUL RHF60
Maximum service temperature of 1200°F
4" insulation for walls and ceiling, 2" floor insulation
Power exhaust
| Blower |
CFM as specified, 2" w.g. @ 70°F
|
| |
CHICAGO SQI 6WF
|
| |
Shaft cooler
|
| |
|
| Motor |
High efficiency TEFC
|
| |
1.5 or 3 HP, as specified
|
| |
1800 or 3600 RPM as specified
|
| |
OSHA guards
|
| |
V-belts type B
|
| |
|
| Chimney |
Chimney diameter based on 15ft high chimney
|
| |
2" ROXUL RHF60 insulation on outlet box
|
| |
Adjustable damper
|
Gasket
Glass fiber high temperature gasket with wiremesh inconel insert
Maximum service temperature 1000°F
Casing
External painted : Steel ASTM36 20GA
Internal : Galvanized steel 18GA
Internal reinforcement : Steel ASTM36 18GA
Reinforcements are placed at insulation extremities, i.e. every
24". Truck wheel guide tracks included.
Paint
Phosphate surface preparation
Two polyurethane coatings.
Handles/Hinges
BRIXON 2PC1
3 to 4 industrial caliber hinges
|