General Electric

Machining Centre / Cast Iron Dust



Summer 2007

Problem

Large quantities of metal dust were produced at the boring stage thereby presenting a potential health hazard to employees.

Solution

A large enclosure with strategic vacuum filtration points was recommended to reduce the amount of dust coming from the production zone. This eliminated the maintenance issue as well as the surrounding environment control issue. The air is filtered and recirculated to surrounding areas within the facility. The pressure in the production zone remains negative to prevent migrating particles from contaminating the surrounding areas.


Specifications

Unit: DCCH-16X2
Power: 15HP
Air Volume: 22000 CFM System
Media: Paper - 10080ft2
Air to Cloth: 2.18:1