Our ovens meet the requirements of NFPA86. They are class B ovens, i.e.
they operate at atmospheric pressure. The ovens must not contain any
volatile, flammable, or combustible material otherwise additional
features must be added in order to meet the requirements for class A
ovens.The following list state the standard specifications of our
models FE500-xxx. Other additional features are also available as
options.
Options
Electrical features
Alarm relay
Alarm strobe light
Alarm buzzer
Open door detector
Circular chart recorder
Digital daily time switch, 7 days/24hours
Hour meter for blower
Incoming disconnect with fuses
Control panel Nema 12
Temperature controller 1/8 din or ¼ din
Programmable temperature controller
Power controller SCR
Mechanical features
Additional features necessary for Class A ovens
Power exhaust
Explosion hatch and venting
Exhaust stack
Thermocouple guard
Motor guard
Shaft/bearing guard
Sliding doors
Automatic door opening device
Electrical specifications
Operating on 600V, 3-phases, 60Hz
Completely wired and tested
Control panel
Terminals for incoming power ( disconnect not included )
Temperature controller 1/16 din with type J thermocouple
Heating and ventilation switches
Pilot light
Heating elements protected in the event of ventilation failure
or high temperature
Control panel Nema 1 meeting the CSA requirements
Mechanical specifications
Blower
CFM as specified for each model, 2 w.g. @ 70F
Selected AIREX SXB model , class 2S
Backward inclined
Shaft cooler
Motor
High efficiency TEFC
Between 1.5 et 10 HP
1800 or 3600 RPM depending on model
OSHA guards
V-belts type B
Heating Elements
Incoloy 840 tubular elements
W shaped
Insulated panel
Removable casing
Insulation
Mineral wool ROXUL RHF60
Maximum service temperature of 1200°F
4 insulation for walls and ceiling, 2" floor insulation
Gasket
Glass fiber high temperature gasket with wiremesh inconel insert
Maximum service temperature 1000°F
Casing
External painted : Steel ASTM36 20GA
Internal : Galvanized steel 18GA
Internal reinforcement : Steel ASTM36 18GA
Reinforcements are placed at insulation extremities, i.e. every
24". Truck wheel guide tracks included.
Paint
Phosphate surface preparation
Two polyurethane coatings.
Handles/Hinges
BRIXON 2PC1
3 to 4 industrial caliber hinges
|